The HOBO Energy Logger Pro Data Logger is a modular, re-configurable data logging system for energy and industrial monitoring applications. View Product Demo
The 15-channel system enables energy and facility management professionals to quickly and easily solve a broad range of monitoring applications without having to purchase a toolbox full of data loggers.
Innovative, snap-in FlexSmart™ signal conditioning modules convert signals from nearly any type of sensor. A suite of pre-defined plug-and-play smart sensors and powerful HOBOware® software make set-up and deployment fast and easy. You can also expand your system capabilities with Ethernet or remote data access communications.
Features:
View Product Demo
Onset's most flexible data logger records up to 15 channels of over a dozen measurements
Provides 12v excitation for third-party sensors
Pre-configured smart sensors get you started fast
Signal conditioning modules retain configurations until you change them, providing plug-and-play convenience for commonly used sensors
Flexible power options include battery operation for AC power adapter
Measurement:
AC Current
Temperature
Relative Humidity
DC Voltage
4-20mA
AC Voltage
Air Velocity
Carbon Dioxide
Compressed Air Flow
DC Current
Kilowatt Hours
Kilowatts
Pressure, Differential
Pressure, Gauge
Pulse
VOC
Water Flow
Wind
specifications:
Operating range: -20° to 50°C (-4° to 122°F) with alkaline batteries
-40° to 60°C (-40° to 140°F) with lithium batteries
Sensor inputs: Three FlexSmart multi-channel modules and up to 6 Smart Sensors (which may have multiple parameters/channels)
Sensor connectors: Six RJ-12 Smart Sensor jacks plus 3 FlexSmart module slots
Communication: RS-232 via 3.5 mm serial port or/and 9-pin D-Sub connector
Dimensions: 15.6 cm x 8.4 cm x 4.6 cm (6.13" x 3.31" x 1.81")
Weight: 435 g (15.23 oz) with batteries 238 g (8.33 oz) without batteries
Memory: 512K nonvolatile flash data storage
Memory modes: Stop when full; wrap when full
Operational indicators: Six indicators provide logging and sensor network status
Logging interval: One second to 18 hours, user-specified interval (2-second minimum for two-channel S-FS-TRMSA operation)
Sensor excitation: 12 V DC at 200 mA total, with user-programmable warmup time on a per-channel basis
Battery life: One year typical use (up to 75 mA excitation with 10-minute or longer logging Interval and 1-second warmup time)
Battery type: Eight standard AA alkaline batteries included (for operating conditions -20°C/-4°F to 50°C/122°F); optional AA lithium batteries available for operating conditions of -40° to 60°C (-40° to 140°F).
External power: Supports optional 13.6 V DC regulated AC Wall Adapter Connector. Internal batteries may remain installed. Alternatively, an automotive battery or 9-12 V DC regulated Wall Adapter may be used, but it is recommended to remove the internal batteries since they will discharge to the level of the external supply.
Time accuracy: 0 to 2 seconds for the first data point and ±5 seconds per week at 25°C (77°F)
Logging mode: Immediate, timed delay, or trigger (button-push) start options; supports sampling intervals for some sensors
Data communication: Current readings while logging; read out while logging;read out when stopped
Producing Area:USA