CLOSED FLUORCAM SYSTEM

CLOSED FLUORCAM SYSTEM

The Z100 Kinetic Multispectral Fluorescence Imaging FluorCam System represents a highly innovative, world-wide used system of multispectral kinetic fluorescence imaging. It consists of a CCD camera, 4 fixed LED panels and 4 or 8 position filter wheel. The LED panels provide uniform irradiance over samples up to 13 x 13 cm – suitable for small plants, detached leaves, algal dilutions, etc. The system allows dark adaptation. The price includes a high-performance PC and comprehensive software package.

Various Light Sources

Super Bright LED panels with different wavelengths
(for example: 390, 450, 470, 505, 570, 605, 630, 735 nm, and others)
STF - Single Turnover Flash
IR 735 nm (FAR)
Ultra high intensity
Actinic Light up to 3000 uE
Super pulse of up 7500 uE
Variable excitation color

 CLOSED FLUORCAM SYSTEM
Different Emission Bands

Filter wheel with 4 or 8 positions
For chlorophyll fluorescence, GFP, YFP, CY3, CY5 and other fluorescence colours
 

Imaging

CCD format: 512 x 512; A/D: 12 bit; 50 images per second (standard)
CCD format: 640 x 480; A/D: 12 bit; 30 images per second (optional)
CCD format: 1392 x 1040; A/D: 12 bit; 15 images per second (optional)

 CLOSED FLUORCAM SYSTEM
Measured Experiments and Parameters

QA - reoxidation
Quenching
Kautsky induction and OJIP
Fast Fluorescence induction with resolution of 1uS
Light curve
Measured parameters (F0, FM, FV, F0', FM', FV', Y(II), Abs PAR-value
Calculated parameters NPQ, FV/FM, FV'/FM', Rfd, qN, qP, PAR-absorptivity, photosynthetic electron transport rate (PS), etc.

 CLOSED FLUORCAM SYSTEM
Sample Size up to 13 cm x 13 cm

384 plate well, 96 plate well, Petri dish, etc.
Selectable shelving system for whole plants 
 CLOSED FLUORCAM SYSTEM

Samples

Leaves, plants, fruits, vegetables
Cyanobacteria, green algae,
Dark room for adaptation


NEW Fluorcam 6.0 Software

Automated experimental protocols via a Windows Wizard
Multiple (automatically repeated) experiments
Automated labeling of individual plants, or samples, within the field of view
Kinetic analysis of data from all samples within the field of view
Numerous image manipulation tools
Barcode reader support
Export to Excel
Windows 2000, XP, Vista.

CLOSED FLUORCAM SYSTEM

Fluorescence parameters

(F0, FM, FV, FO', FM', FV', Y(II), Abs PAR-value or parameters that are calculated from the fluorescence emission (e.g. NPQ, FV/FM, FV'/FM', Rfd, qN, qP) PAR-absorptivity, photosynthetic electron transport rate (PS) and others

Excitation light sources

360, 390, 450, 470, 505, 570, 605, 630 and 735nm (others available)

Saturating light intensity

  • Blue
  • Red
  • White
  • Actinic
  • up to 6000 uE
  • up to 7500 uE
  • up to 5000 uE
  • up to 3000 uE

Filter wheel

4 or 8 positions

Light regime

Static or dynamic (sinus form)

Custom defined protocols

Variable timing, special language and scripts

CCD detector wavelength range

400 -1000nm

A/D bit resolution

12 bit

Spectral response

QE max at 540nm (~70%), 50% roll-off at 400nm and 650nm

Readout noise

Less than 12 electrons RMS - typically only 10 electrons

Full-well capacity

Greater than 70,000 e- (unbinned)

Imaging frequency

50 fps

Bios

Upgradeable firmware

Communication port

USB 2.0

Dimensions

480mm x 480mm x 530mm

Weight

40 kg

Electrical

90-240V

Producing Area:Canada