Other Enclosure Accessories

7363 Enclosure Supply Kit

The Enclosure Supply Kit is included with our standard enclosures, but can be purchased separately. The assembled equipment aides in mounting your equipment inside the enclosure as well as monitoring relative humidity and sealing the enclosure.

Other Enclosure Accessories

Features

Includes desiccant packs, humidity indicator card, cable ties, putty, screws, grommets, and a Philips screwdriver.


CS210 Enclosure Humidity Sensor

This small, inexpensive relative humidity sensor is housed inside the enclosure. The sensor is measured by the datalogger; the measured RH value can then be stored in the datalogger.

Other Enclosure Accessories

Features

Used to schedule desiccant replacement
Senses relative humidity inside the environmental enclosure
Allows enclosure RH to be monitored remotely

Specifications

Sensor: Elan HM2000 series precision bulk-polymer
Relative Humidity Measurement Range: 0 to 100% non-condensing
RH Output Signal Range: 0 to 1.0 Vdc
Accuracy at 25°C: ±3% RH (10 to 90% RH)
Typical Long Term Stability: Better than 3% RH per year
Response Time (at 25°C, 90% response): 10 seconds for a 30% to 90% RH step change
Current Consumption: <0.5 mA
Supply Voltage: 5 ± 0.25 Vdc
Settling Time: 10 seconds


6714 Desiccant Four-Unit Bag (Qty 20)

The 6714 (ordered as the DSC 20/4 prior to 1 September 2005) includes twenty 4-unit Silica Gel Desiccant Bags. Multi-packs are recommended for customers who need to desiccate multiple enclosures or systems.

Other Enclosure Accessories


3885 Desiccant Half-Unit Bag (Qty 50)

The 3885 (ordered as DSC 50/2 prior to 1 September 2005) includes fifty half-unit (0.5) desiccant bags. Multi-packs are recommended for customers who need to desiccate multiple enclosures or systems.

Other Enclosure Accessories


6571 Humidity Indicator Card

The 6571 card provides a visual reference of humidity level inside the enclosure. Colored circles change color from blue to pink to indicate humidity levels of 30%, 40%, and 50% relative humidity.
Because the water vapor contained in the atmosphere will begin to affect the card once the enclosure is opened, the card should be inspected immediately after the enclosure is opened. Desiccant inside of the enclosure should be replaced when relative humidity exceeds 35%.

Other Enclosure Accessories

Features

Included in the enclosure supply kit
Can be ordered individually as a replacement item


SVP48 Surge Voltage Protector Bracket
 
The SVP48 is a DIN-rail bracket that holds up to 22 of the 8206 surge protectors. This bracket mounts to the backplate of our standard enclosures.
The 8206 protects a datalogger against electrical transients conducted along the sensor cables. The surge protectors trigger at 110 Vac or 156 Vdc; voltages exceeding those levels are shunted to ground. The surge protectors are rated for 125 Vac or 177 Vdc. The voltage limitation is 650 V at 1 kV/microsecond. Each surge protector protects one signal conductor and provides a termination for one shield wire. The 8206 is ordered as a separate line item.

Other Enclosure Accessories

Features

Surge protection provided by gas filled arrestors that trigger at 110 VAC or 156 VDC.
Each surge protector protects one conductor and provides a terminal for shield wires. 

Producing Area:USA