The LI200X Silicon Pyranometer is calibrated against an Eppley precision spectral pyranometer (PSP) to accurately measure sun-plus-sky radiation. The LI200X is used extensively in solar, agricultural, and meteorological applications. The LI200X should not be used under vegetation or artificial lights because it is calibrated for the daylight spectrum (400 to 1100 nm).
Features
Measures sun-plus-sky radiation
Measurement waveband: 400 to 1100 nm
Uses a silicon photovoltaic detector
Should not be used under vegetation or artificial lights
Manufactured by LI-COR
Mounts to a tripod mast, tower leg, or crossarm via the LI2003S leveling base and CM225 solar radiation mount
Specifications
Light Spectrum Waveband: 400 to 1100 nm
Accuracy: Absolute error in natural daylight is ±5% maximum; ±3% typical
Sensitivity: 0.2 kW m-2 mV-1
Linearity: Maximum deviation of 1% up to 3000 W m-2
Shunt Resistor: Adjustable, 40.2 to 90.2 ohm, factory set to the above sensitivity
Stability: <±2% change over a 1 year period
Response Time: 10 μs
Temperature Dependence: 0.15% per °C maximum
Cosine Correction: Cosine corrected up to 80° angle of incidence
Detector: High stability silicon photovoltaic detector (blue enhanced)
Sensor Housing: Weatherproof anodized aluminum case with acrylic diffuser and stainless steel hardware
Producing Area:USA