DAQ-G1S

DAQ-G1S

The DAQ-G1S is a single channel system for measuring oxygen consumption rates of aquatic organisms in static or swim measurements. It includes user-friendly Win98/2000/XP software and a USB instrument for an easy and effortless approach to intermittent flow respirometry.
 

FEATURES

Automatic oxygen consumption measurements on aquatic organisms by intermittent flow respirometry
Data acquistion, analysis and graphical presentation of respirometric data
Measurement of one chamber O2 signal

DAQ-G1S SYSTEM INCLUDES


DAQ-1 USB instrument (for use with 1 respirometer chamber)
Power: 110/230VAC, 50/60Hz
PC interface: USB1.1
Resolution: 16-bit
Analog inputs: 4 x 0-5VDC
Output relays: 4 x 110/230VAC (3A)
Dimensions (W x D x H): 210 x 200 x 74mm
Weight: 1.2 kg
AutoResp®1 software for WinXP
Power cord
USB cable
Adapter cable for pumps (2)
Input connectors (3)
Device connectors (2)
User Manual
D901 Dissolved Oxygen Probe (MINI)
D905-MINI maintenance kit
D201 Signal conditioning instrument (for D901 DO2 Probe (MINI))
Input connector
Device connector
Power cord
Data cable
User manual 

DAQ-G1S


**DAQ-G1S SYSTEM DOES NOT INCLUDE**

This package does NOT include pumps or tubing. Qubit can provide submersible pumps, as shown below:

ITEM #

Maximum Output(LPH)

Delivery Head(m)

Hose Connection (mm)

Dimensions (mm)

Suction Side

Pressure Side

D113-4.5

270

0.75

17

13

87 x 66 x 88

D113-10

600

1.5

13

13

147 x 75 x 118

D113-20

1200

2.0

17

13

180 x 95 x 120

D113-40

2400

3.7

28

18

218 x 116 x 161

D113-57

3400

3.6

28

18

218 x 116 x 161

This package does NOT include respirometry chambers. Qubit can provide chambers, as shown below:

SOFTWAR

ITEM #

Internal Diameter(mm)

Length(mm)

Material

D002

100

Custom

ACRYLIC

D003

62

Custom

GLASS

D004

54

21.5

ACRYLIC

D007

33

Custom

GLASS

D008

45

Custom

GLASS

D009

72

Custom

ACRYLIC

D010

140

Custom

ACRYLIC

E AND HARDWARE FOR AUTOMATED RESPIROMETRY

Use our AutoResp® software and DAQ instruments to measure oxygen consumption rates (MO2) of aquatic organisms by intermittent flow (or stop flow) respirometry, and control experimental pumps, water temperature and oxygen saturation in the water automatically.

Features

Fully automated MO2 measurements in aquatic organisms (i.e. fish, aquatic invertebrates etc.) with unbeaten time resolution.
On-the-fly data acquistion, analysis and graphical presentation of respirometric data.
Automatic control of experimental pumps, ambient water temperature and oxygen saturation.
In short, the system will

Collect oxygen data from the respirometer chamber via isolated pre-amplifier and A/D device (or directly from fiber-optic instrument's software).
Calculate oxygen consumption rates during each measuring period. Raw and calculated data are saved in an Excel compatible file format.
Control activity of experimental pumps via digital-controlled 110/240V relays (3A) for mixing and flushing between measuring periods.
Control ambient water oxygen partial pressure from optional oxygen probe (in ambient tank) input to preset value via relay and solenoid (optional).
Correct for solid blocking effects during swim respirometry experiments, allowing swimming speed to be read and controlled as body lengths per second, rather than cm per second.
Repeatedly determine oxygen consumption rate every 5 - 10 min.
Graph analyzed data (e.g. MO2 vs. Time, MO2 vs. Swim speed, MO2 vs. O2 etc.) during experiments.
Control ambient water temperature from optional temperature input.
AND MUCH MORE............

Basic functions

Calibrating sensor inputs and converting them into engineering units
Run intermittent flow (or stop flow) respirometry experiments automatically
Perform online data analysis, statistics and graphical displays
Save all raw and calculated data in a text file.

Software copy protection

The AutoResp® software comes with a USB hardkey dongle.

Specifications

Windows 98/2000/XP or Vista
Intel Pentium IV processor of minimum 2.66 GHz or equivalent
256 MB memory
1GB of free hard disk space
Minimum resolution of 1024x768 pixels is required.

Graphs

Chamber O2 vs. Time
Ambient O2 vs. Time
MO2 vs. Time
MO2 vs. avg chamber O2
MO2 vs. avg Uwater
MO2 vs. Uswim
avg Temp vs. Time
Current temp vs. Time
R2 vs. Time
Current R2 vs. Time

Screen Samples
Calibration Menu                  Static Experiment Setup Menu      Swim Experiment Setup Menu

DAQ-G1S          DAQ-G1S          DAQ-G1S            

Producing Area:Denmark