The SF-G sensor is the typical Granier sensor and consists of two needles
Advantages
- Suitable for tree diameter >2 cm
- Reusable sensor
Limits
- Temperature difference between the needles is superimposed by natural vertical temperature gradients within the sap wood (up to + / -2.5 ° C). This occasionally leads to unpredictable errors of over 50% in sap flow calculations.
- Sap flow at night cannot be measured. Due to unpredictable temperature overlays, night values are wrongly set to zero.
Available Models
- SF-G 20/33, depth of installation 20-33 mm
- SF-G 20/43, depth of installation 20-43 mm
- SF-G 20/63, depth of installation 20-63 mm
Delivery by Standard Version
- Sensor with 5 cable, weatherproof cap, Aluminium tubes
Options / Ordering Information
- Cable extension (please specify in meters, but max. 20 m)
- CCS power supply (one CCS is enough for up to 3 SF-G sensors)
- Installation tools
- Data Logger
Technical data
Name | Sap Flow Sensor Type SF-G |
Needle size | Diameterr 1.5 mm, Length 33, 43, 63 mm |
Cable length | 5 m, extendable to 20 m |
Suitable for tree size | Diameter> 2 cm |
Power supply | A CCS supplies up to 3 sensors and consumes 1 W (12 V x 84 mA DC, stabilized) |
Output | 0 µV bis 1000 µV DC |