The SC105 Interface supports communications between a Campbell Scientific datalogger and an RS-232 DCE device. Common DCE devices used with the SC105 include our Raven100, Redwing100, and Redwing105 cellular transceivers as well as third-party radios and modems. The SC105 provides internal buffering that temporarily stores data. This allows the datalogger and DCE device to operate at different baud rates by storing the data received from the faster device until the slower device is ready to receive it. Internal buffering also ensures that no data is lost during transmission.
Features
Supports communication between a datalogger and an RS-232 DCE device
Allows DCE devices to communicate with our dataloggers at rates up to 115.2 kbps
Provides internal buffering capability to ensure no data is lost during transmission
Specifications
Baud rates Supported: 1200, 9600, 19200, 38400, 57600, 115200
RS-232 Parity Supported: even, odd, none
RS-232 Data Bits Supported: 7, 8
CS I/O port modes: CSDC, SDC, ME, Addressed Print Device for P96 output
Power Source: Datalogger’s 5 V supply
Current Drain*
Standby: 0.16 mA
While Communicating: 1 to 4 mA
*Additional current (up to 8 mA) may be used by the DCE device connected to the SC105.
Producing Area:USA