T-CON-ACT-150

T-CON-ACT-150

0-150 volt self-powered transformer for monitoring sine wave, single-phase AC voltage. Requires Input Cable for use with U12 loggers.

Features:

Can be plugged directly into the external input jacks of U12 Family loggers to expand the range of measurement options and applications.

Specifications:
 
Ranges: 0–150 volts RMS
Sensor accuracy: < ±0.1% of span (20% to 120% of range) ±0.25% of span (10% of range)
Over range: +20% of span
Over load: +40% of span
Frequency: 60 Hz AC
Supply: Self-powered
Output: 0–20 mA
Response time to 90%: <240 msec
Operating Conditions: -20° to 70°C (-4° to 158°F); 5-95% RH, non-condensing
Housing: Plastic polycarbonate
Protection Level:
Box: According to IP-50 DIN 40050
Terminals: According to IP-10 DIN 40050
Mounting: Standard 35mm DIN rail

Notes: Because these sensors tie directly into the line, they should be used only by qualified personnel.

Producing Area:USA